Technical specifications
Table 73. Mechanics
|
Type |
Value |
|---|---|
|
Casing material |
Polyamide |
|
Protection class |
IP20 |
|
Dimensions (w x h x d) |
35 x 100 x 65 mm (2 DIN modules) |
|
Mounting DIN-rail (DIN 50022) |
35 mm |
|
Weight |
120 g |
|
SIM card |
Push-push type |
|
Antenna |
SMA female |
Table 74. Electrical connections
|
Type |
Value |
|---|---|
|
Supply voltage |
Screw terminal. Cable 0.5-2.5 mm², 0.5 Nm tightening torque |
|
M-Bus master port |
Screw terminal. Cable 0.2-1.5 mm² |
|
USB master port |
Type A |
|
USB slave port |
Type micro B |
|
Network |
Mobile networks (2G/3G/LTE) |
Table 75. Electrical characteristics
|
Type |
Value |
|---|---|
|
Nominal voltage |
100-240 VAC (±10%) |
|
Frequency |
50/60 Hz |
|
Power consumption (max) |
<6 W |
|
Power consumption (nom) |
<1 W |
|
Installation category |
CAT 3 |
Table 76. Environmental specifications
|
Type |
Value |
|---|---|
|
Operating temperature |
-20 to +55 °C |
|
Operating humidity max |
80 % RH at temperatures up to 31 °C, decreasing linearly to 50 % RH at 55 °C |
|
Operating altitude |
0-2000 m |
|
Pollution degree |
Degree 2 |
|
Usage environment |
Indoors (can be extended with IP67 enclosure for outdoor use) |
|
Storage temperature |
-40 to +85 °C |
Table 77. User interface
|
Type |
Value |
|---|---|
|
Green LED |
Power |
|
Red LED |
Error |
|
Yellow LED |
Network status |
|
Blue LED |
Meter installation, reboot |
|
Push button |
Factory reset |
|
Configuration |
SMS, HTTP, Telnet |
Table 78. Approvals
|
Type |
Value |
|---|---|
|
EMC |
EN 61000-6-2, EN 61000-6-3, EN 301489-1, EN 301489-7, etc. |
|
Safety |
IEC 61010-1:2010 + A1:2016 |
Table 79. M-Bus
|
Type |
Value |
|---|---|
|
Interfaces |
IR, integrated M-Bus Master |
|
M-Bus standard |
EN 13757, full M-Bus decoder implemented |
|
Transparent M-Bus |
NET and TCP/IP (software limit does not apply to Transparent M-Bus mode) |
|
Decryption |
Yes |
Table 80. Integrated M-Bus Master
|
Type |
Value |
|---|---|
|
M-Bus baud rate |
2400 and 9600 bit/s |
|
Nominal voltage |
28 VDC |
|
Maximum unit loads |
16/24 T/mA (Can be extended with CMeX10-13S series) |
|
Maximum numbers of M-Bus devices |
256 |
|
M-Bus search modes |
Primary, secondary |
|
Maximum cable length |
1000 m (100 nF/km, maximalt 90 Ω) |
Table 81. General
|
Type |
Value |
|---|---|
|
Real-time clock accuracy |
<2 s/day |
|
Script engine |
Intelligent script engine for active content generation |
|
Software update |
HTTP |
|
Measurement reports |
HTTP, FTP, SMTP (e-mail), SMS |
|
Real-time clock backup |
12 h |
Table 82. Data storage (examples)
|
Type |
Value |
|---|---|
|
1 meter |
15-minute values: 200 days Hourly values: 800 days |
|
32 meters |
15-minute values: 6 days Hourly values: 25 days |
|
64 meters |
15-minute values: 3 days Hourly values: 12 days |
|
128 meters |
15-minute values: 1 day Hourly values: 6 days |
Comments (0 comments)