Technical specifications

Table 73. Mechanics

Type

Value

Casing material

Polyamide

Protection class

IP20

Dimensions (w x h x d)

35 x 100 x 65 mm (2 DIN modules)

Mounting DIN-rail (DIN 50022)

35 mm

Weight

120 g

SIM card

Push-push type

Antenna

SMA female


Table 74. Electrical connections

Type

Value

Supply voltage

Screw terminal. Cable 0.5-2.5 mm², 0.5 Nm tightening torque

M-Bus master port

Screw terminal. Cable 0.2-1.5 mm²

USB master port

Type A

USB slave port

Type micro B

Network

Mobile networks (2G/3G/LTE)


Table 75. Electrical characteristics

Type

Value

Nominal voltage

100-240 VAC (±10%)

Frequency

50/60 Hz

Power consumption (max)

<6 W

Power consumption (nom)

<1 W

Installation category

CAT 3


Table 76. Environmental specifications

Type

Value

Operating temperature

-20 to +55 °C

Operating humidity max

80 % RH at temperatures up to 31 °C, decreasing linearly to 50 % RH at 55 °C

Operating altitude

0-2000 m

Pollution degree

Degree 2

Usage environment

Indoors (can be extended with IP67 enclosure for outdoor use)

Storage temperature

-40 to +85 °C


Table 77. User interface

Type

Value

Green LED

Power

Red LED

Error

Yellow LED

Network status

Blue LED

Meter installation, reboot

Push button

Factory reset

Configuration

SMS, HTTP, Telnet


Table 78. Approvals

Type

Value

EMC

EN 61000-6-2, EN 61000-6-3, EN 301489-1, EN 301489-7, etc.

Safety

IEC 61010-1:2010 + A1:2016


Table 79. M-Bus

Type

Value

Interfaces

IR, integrated M-Bus Master

M-Bus standard

EN 13757, full M-Bus decoder implemented

Transparent M-Bus

NET and TCP/IP (software limit does not apply to Transparent M-Bus mode)

Decryption

Yes


Table 80. Integrated M-Bus Master

Type

Value

M-Bus baud rate

2400 and 9600 bit/s

Nominal voltage

28 VDC

Maximum unit loads

16/24 T/mA (Can be extended with CMeX10-13S series)

Maximum numbers of M-Bus devices

256

M-Bus search modes

Primary, secondary

Maximum cable length

1000 m (100 nF/km, maximalt 90 Ω)


Table 81. General

Type

Value

Real-time clock accuracy

<2 s/day

Script engine

Intelligent script engine for active content generation

Software update

HTTP

Measurement reports

HTTP, FTP, SMTP (e-mail), SMS

Real-time clock backup

12 h


Table 82. Data storage (examples)

Type

Value

1 meter

15-minute values: 200 days

Hourly values: 800 days

32 meters

15-minute values: 6 days

Hourly values: 25 days

64 meters

15-minute values: 3 days

Hourly values: 12 days

128 meters

15-minute values: 1 day

Hourly values: 6 days


Table 83. Mobile network

Type

Value

GPRS class

Up to 12

Band

850/900/1800/1900 MHz