Technical specifications
Table 277. Mechanics
Type |
Value |
---|---|
Casing material |
Polyamide |
Protection class |
IP20 |
Dimensions (w x h x d) |
CMeX10, CMeX11 : 36 x 90 x 65 mm (3 modules wide) CMeX10S, CMeX11S, CMeX12S, CMeX13S: 108 x 90 x 65 mm (7 modules wide) |
Weight |
CMeX10, CMeX11: 100 g CMeX10S, CMeX11S, CMeX12S, CMeX13S: 220 g |
Connection M-Bus |
CMeX10, CMeX11 : Pin terminal (solid wire 0.6 - 0.8 Ø mm) CMeX10S, CMeX11S, CMeX12S, CMeX13S: Pin terminal and screw terminal (screw terminal: cable 0 - 2.5 mm 2, 0.5 Nm tightening torque) |
Mounting |
DIN-mounted |
Power supply |
Screw terminal (cable 0.75 - 2.5 mm2, 0.5 Nm tightening torque) |
Table 278. Electrical
Type |
Value |
---|---|
Nominal voltage |
100 - 240 VAC |
Voltage range |
-10 - +10 % of nominal voltage |
Frequency |
50/60 Hz |
Power consumption (max) |
CMeX10, CMeX11 : 6 W CMeX10S, CMeX11S, CMeX12S, CMeX13S: 25 W |
Power consumption (nom) |
CMeX10: 3.5 W CMeX11: 6 CMeX10S, CMeX11S, CMeX12S, CMeX13S: 0,07 W X number of M- Bus slaves + 1, 5W |
Power consumption M-Bus (max) |
CMeX10: 50 mA CMeX11: 100 mA |
Installation category |
CAT3 |
Table 279. Environmental specifications
Type |
Value |
---|---|
Operating temperature |
-30 to +55 ºC |
Operating humidity max. |
80 % RH (temperatures up to 31 °C, decreasing linearly to 50 %RH at 40 °C) |
Operating altitude |
0-2000 m |
Pollution degree |
Degree 2 |
Usage environment |
Indoors (can be extended with IP67 enclosure for outdoor use) |
Storage temperature |
-40 to +85 ºC |
Table 280. User interface
Type |
Value |
---|---|
Green LED |
Power |
Red LED |
Error |
Yellow LED |
RX |
Yellow LED |
TX |
Push button |
Not used |
Table 281. M-Bus
Type |
Value |
---|---|
Maximum connected M-Bus slaves |
CMeX10, CMeX11 : 32-64 CMeX10S, CMeX11S, CMeX12S, CMeX13S: 32-256 CMeX10: 32 M-Bus slaves CMeX11: 64 M-Bus slaves CMeX10S: 32 M-Bus slaves CMeX11S: 64 M-Bus slaves CMeX12S: 128 M-Bus slaves CMeX13S: 256 M-Bus slaves |
Maximum cable length |
CMeX10, CMeX11: 1000 m CMeX10S, CMeX11S, CMeX12S, CMeX13S: 5000 m |
Maximum load capacitance |
1.5 uF |
Light collision detect |
>28 to 500 mA |
Heavy collision detect and short circuit |
>500 mA |
RS232 to M-Bus |
CMeX10, CMeX11: No CMeX10S, CMeX11S, CMeX12S, CMeX13S: Yes |
Break signal length M-Bus 2- wire and right IR interface |
45 ms |
Break signal RS232 interface and left IR interface |
45 ms break+ garbage 200ms 45 ms break This method is used for garbage generation when using other bearer than RS232, i.e. TCP/IP. |
Nominal voltage |
CMeX10, CMeX11: 28 VDC CMeX10S, CMeX11S, CMeX12S, CMeX13S: 42 VDC |
Maximum idle current |
CMeX10: 55 mA CMeX11:100 mA CMeX10S: 55 mA CMeX11S: 100 mA CMeX12S: 200 mA CMeX13S: 400 mA |
IR interface |
Yes |
Pass through |
Yes (maximum of 4 products side by side) |
Compatibility |
All standard M-Bus meters, all ABB meters with IR interface, CMeX Series products |
Table 282. Approvals
Type |
Value |
---|---|
EMC |
CMeX10, CMeX11: EN 61000-6-2, EN 61000-6-3 CMeX10S, CMeX11S, CMeX12S, CMeX13S: EN 61000-6-2, EN 61000-6-3, FCC 47 CFR |
Safety |
CMeX10, CMeX11: EN 61010-1, CAT 3 CMeX10S, CMeX11S, CMeX12S, CMeX13S: EN 62368-1 2018, UL 62368-1:2014 Ed.2], CSA C22.2#62368-1:2014 Ed.2] |
Comments (0 comments)