Release notes

CMi4160 1.0.9

Release date: 2026-05-18

Notes: This release doesn't introduce any new firmware features. The release is done to make the firmware compatible with the newly released CMi4160 hardware. The firmware also includes improved handling of meter values during error states, preventing invalid BCD values from being reported as misleading numeric readings.

The new hardware has an updated mechanical design and includes the following improvements

  • New NFC antenna design to improve interaction with the Elvaco OTC app

  • On-board antenna connector. Enables the antenna choice, internal or external, to be changed after deployment.

  • Improved physical fit in Diehl SCYLAR INT8. The CMi4160 is now mechanically aligned with the sister modules CMi6160 for NB-IoT and CMi7160 for OMSv5/mioty communication, providing a better fit in Diehl’s SCYLAR INT 8 energy calculator. This also means that the battery connector has been changed to be the same as for CMi6160 and CMi7160 as well.

Note

The new HW for CMi4160 G2 comes with its own JoinEUI - 0x94193A0310000001. This might affect existing LoRaWAN® server implementations. If so, make sure to adapt the implementation to the new JoinEUI for a proper join procedure and connection.

Note

Note that the battery connector has been changed for the new HW version. Nevertheless, this has no functional effect of the product.

Table 338. Implemented changes

ID

Description

MCM-8672

Port HW changes for supporting CMi4160-G2 HW

MCM-7304

[SOLVED] BCD conversion not correctly handling non-numeric values from meter


CMi4160 1.0.8

Release date: 2026-03-04

Notes: This release introduces a new message format, Max flow, which includes the maximum flow rate during the last logging period, along with the date when it occurred. See Maximum flow for a complete message format specification.

Warning

This format is only useful in meters with FW version 3 or higher since it relies the logger functionality of the meter which was introduced in meter FW 03.

Note

The value/date of the maximum flow is taken from the meters log. The log can be configured in the meter for different intervals (hourly, daily, weekly, monthly etc.) and thus the value sent depends on how the meter is configured.

Table 339. Implemented changes

ID

Description

MCM-8576

Add new message format Max Flow

MCM-7304

Add support for FW06 for Diehl Sharky without encryption


CMi4160 1.0.7

Release date: 2025-05-13

Notes: This release address an issue that was introduced in FW 1.0.6 when dealing with tariffs. It also fixes an issue that could show up in certain LoRaWAN® network server environment, unexpectedly dropping telegrams. Lastly, it corrects the the encoding of the error codes received if the meter communication is not working.

Table 340. Implemented changes

ID

Description

MCM-7633

[SOLVED] Fix compatibility with some LoRa networks

MCM-7402

[SOLVED] Tariff information still present in transmission payload after changing Tariff unit in meter

MCM-7694

[SOLVED] Error codes wrongly encoded when meter communication is not working


CMi4160 1.0.6

Release date: 2025-01-31

Notes: In previous releases, CMi4160 does not handle tariff registers other than energy. This release makes it possible to also handle volume and time tariffs. Please note! If changing tariff settings in the meter, make sure the CMi4160 is rebooted afterwards to ensure proper tariff handling. Reboot can be triggered either remotely via LoRaWAN downlink, or locally via the Elvaco OTC App.

Table 341. Implemented changes

ID

Description

MCM-7130

Handle tariff data with different units (Energy/Volume/Time)

MCM-7387

[SOLVED] Messages sent at startup or manually triggered should not have timestamp rounding


CMi4160 1.0.5

Release date: 2022-09-16

Notes: Implements a new message format, Schedule Extended+

Table 342. Implemented changes

ID

Description

MCM-2608

Message format Scheduled Extended+ added


CMi4160 1.0.4

Release date: 2020-11-23

Notes: Firmware change to comply with ETSI duty cycle requirements

Table 343. Implemented changes

ID

Description

MCM-2366

Adapt to ETSI duty cycle requirements


CMi4160 1.0.3

Release date: 2020-05-06

Notes: Adjusted an error in the JSON message format.

Table 344. Implemented changes

ID

Description

MCM-1724

[Solved] MeterID in JSON format sent as null


CMi4160 1.0.2

Release date: 2020-03-20

Notes: Adapting the EcoMode table to manage both one A-Cell and two A-Cell to be used as source of power.

Table 345. Implemented changes

ID

Description

MCM-1568

EcoMode table updated to be able to manage other battery configurations than one A-Cell


CMi4160 1.0.1

Release date: 2020-02-

Notes: This is the first commercially available firmware release of the product.