Table 50. Mechanics
|
Type |
Value |
|---|---|
|
Casing material |
Polyamide |
|
Protection class |
IP20 |
|
Dimensions |
62 x 30 x 36 mm |
|
Weight |
32 g |
|
Mounting |
In a Landis+Gyr UH50/UC50 |
Table 51. Electrical connections
|
Type |
Value |
|---|---|
|
Cable wire area |
1.0 mm2 |
|
Fuse protection |
No internal fuse |
Table 52. Electrical characteristics
|
Type |
Value |
|---|---|
|
Nominal voltage |
12-35 VAC / 12-50 VDC |
|
Frequency |
50/60 Hz |
|
Power consumption |
<2.5 W |
|
Backup time during power failure |
~30 minutes before error code F4 appears |
Table 53. Electrical characteristics, output 1 (meter, 3pol)
|
Type |
Value |
|---|---|
|
Nominal voltage |
4.6-5.1 VDC |
|
Minimum load |
0 mA |
|
Maximum load |
10 mA |
|
Primary power good indicator |
4.8-6.0 VDC |
Table 54. Electrical characteristics, output 2 (meter, 2pol)
|
Type |
Value |
|---|---|
|
Nominal voltage |
3.6-4.3 VDC |
|
Minimum load |
0 mA |
|
Maximum load |
500 mA |
Table 55. Environmental specifications
|
Type |
Value |
|---|---|
|
Operating temperature range |
-20 to +55 °C |
|
Operating humidity |
5 to 90 %, no condensation |
|
Operating altitude |
0-2000 m |
|
Pollution degree |
Degree 2 |
|
Usage environment |
lndoors |
|
Storage temperature range |
-25 °C to +70 °C |