Technical specifications

Table 204. Mechanics

Type Value
Protection class IP54
Dimensions (w x h x d) 80 x 38 x 23 mm
Weight 35 g
Mounting In Landis+Gyr UH50/UC50 module slot 2
External antenna connector SMA female


 

Table 205. Electrical connections

Type Value
Supply voltage

Internal meter battery or PSU

PSU options: Elvaco CMip2110 230V, Landis+Gyr WZU-AC230-XX


 

Table 206. Electrical characteristics

Type Value
Nominal voltage 3.0 - 5.0 VDC
Power consumption (max) 40 mA
Power consumption (sleep mode) 2.2 µA


 

Table 207. Environmental specifications

Type Value
Operating temperature 5 - 55 ºC
Operating humidity 0 - 93 % RH, no condensation
Operating altitude 2000 m
Pollution degree Degree 1
Usage environment Indoors
Storage temperature -20 - 60 ºC


 

Table 208. Radio characteristics

Type Value
Frequency 868 MHz
Output power 14 dBm
Receiver sensitivity -135 dBm


 

Table 209. LoRaWAN® characteristics

Type Value
Device class Class A, bi-directional
LoRa version 1.0
Activation OTAA or ABP
Data rate DR0 - DR5 (250 – 5470 bit/s)
Join-EUI 0x0000000000000000


 

Table 210. User interface

Type Value
Green LED Status
Red LED Error
Push button Start-up / reboot / switch off module
Configuration NFC via Elvaco OTC app or downlink data


 

Table 211. Approvals

Type Value
EMC EN 301 489-1, EN 301 489-3


 

European standards

  • M-Bus standard EN 13757-3:2013: Communication systems for and remote reading of meters – Part 3: Dedicated application layer

Was this article helpful?

0 out of 0 found this helpful
Have more questions? Submit a request

Comments (0 comments)